Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances - ICH Topic Q6A

Date Adopted: 2016/01/29
Effective Date: 2016/01/29

Notice

January 29, 2016

Our file number: 16-100136-12

Adoption of International Conference on Harmonisation of Technical Requirements for the Registration of Pharmaceuticals for Human Use (ICH) Guidance Document: Q6A: Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances

Health Canada is pleased to announce the adoption of the ICH guidance document Q6A: Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products: Chemical Substances.

This guidance has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. The ICH Steering Committee has endorsed the final draft and recommended its adoption by the regulatory bodies of the European Union, Japan and USA.

In adopting this ICH guidance, Health Canada endorses the principles and practices described therein. This document should be read in conjunction with this accompanying notice and with the relevant sections of other applicable Health Canada guidances.

It is recognized that the scope and subject matter of current Health Canada guidances may not be entirely consistent with those of the ICH guidances that are being introduced as part of our commitment to international harmonization and the ICH Process.  In such circumstances, Health Canada adopted ICH guidances take precedence.

Health Canada is committed to eliminating such discrepancies through the implementation of a phased-in work plan that will examine the impact associated with the adoption of ICH guidances. This will result in the amendment or, depending on the extent of revisions required, withdrawal of some Health Canada guidances.

This and other Guidance documents are available on the Health Canada website.

Should you have any questions or comments regarding the content of the guidance, please contact:

BPS Enquiries - Bureau of Pharmaceutical Sciences
E-mail: bps_enquiries@hc-sc.gc.ca
Telephone: 613-941-3184
Fax: 613-941-0571

Foreword

This guidance has been developed by the appropriate ICH Expert Working Group and has been subject to consultation by the regulatory parties, in accordance with the ICH Process. The ICH Steering Committee has endorsed the final draft and recommended its adoption by the regulatory bodies of the European Union, Japan and the United States of America.

In adopting this ICH guidance, Health Canada endorses the principles and practices described therein.  This document should be read in conjunction with the accompanying notice and the relevant sections of other applicable guidances.

Guidance documents are meant to provide assistance to industry and health care professionals on how to comply with the policies and governing statutes and regulations.  They also serve to provide review and compliance guidance to staff, thereby ensuring that mandates are implemented in a fair, consistent and effective manner.

Guidance documents are administrative instruments not having force of law and, as such, allow for flexibility in approach.  Alternate approaches to the principles and practices described in this document may be acceptable provided they are supported by adequate scientific justification.  Alternate approaches should be discussed in advance with the relevant program area to avoid the possible finding that applicable statutory or regulatory requirements have not been met.

As a corollary to the above, it is equally important to note that Health Canada reserves the right to request information or material, or define conditions not specifically described in this guidance, in order to allow the Department to adequately assess the safety, efficacy or quality of a therapeutic product.  Health Canada is committed to ensuring that such requests are justifiable and that decisions are clearly documented.

Document History
First Codification History Date New Codification
November 2005
Q6A Approval by the Steering Committee under Step 2 and release for public consultation. 18 July 1997 Q6A
Current Step 4 version
Q6A Approval by the Steering Committee under Step 4 and recommendation for adoption to the three ICH regulatory bodies. 6 October 1999 Q6A

Table of contents

1. Introduction

1.1 Objective of the Guideline

This guideline is intended to assist to the extent possible, in the establishment of a single set of global specifications for new drug substances and new drug products. It provides guidance on the setting and justification of acceptance criteria and the selection of test procedures for new drug substances of synthetic chemical origin, and new drug products produced from them, which have not been registered previously in the United States, the European Union, or Japan.

1.2 Background

A specification is defined as a list of tests, references to analytical procedures, and appropriate acceptance criteria, which are numerical limits, ranges, or other criteria for the tests described. It establishes the set of criteria to which a drug substance or drug product should conform to be considered acceptable for its intended use. "Conformance to specifications" means that the drug substance and / or drug product, when tested according to the listed analytical procedures, will meet the listed acceptance criteria. Specifications are critical quality standards that are proposed and justified by the manufacturer and approved by regulatory authorities as conditions of approval.

Specifications are one part of a total control strategy for the drug substance and drug product designed to ensure product quality and consistency. Other parts of this strategy include thorough product characterization during development, upon which specifications are based, and adherence to Good Manufacturing Practices; for example (e.g.), suitable facilities, a validated manufacturing process, validated test procedure, raw material testing, in-process testing, stability testing, etc.

Specifications are chosen to confirm the quality of the drug substance and drug product rather than to establish full characterization, and should focus on those characteristics found to be useful in ensuring the safety and efficacy of the drug substance and drug product.

1.3 Scope of the Guideline

The quality of drug substances and drug products is determined by their design, development, in-process controls, GMP controls, and process validation, and by specifications applied to them throughout development and manufacture. This guideline addresses specifications, that is (i.e.), those tests, procedures, and acceptance criteria which play a major role in assuring the quality of the new drug substance and new drug product at release and during shelf life. Specifications are an important component of quality assurance, but are not its only component. All of the considerations listed above are necessary to ensure consistent production of drug substances and drug products of high quality.

This guideline addresses only the marketing approval of new drug products (including combination products) and, where applicable, new drug substances; it does not address drug substances or drug products during the clinical research stages of drug development. This guideline may be applicable to synthetic and semi-synthetic antibiotics and synthetic peptides of low molecular weight; however, it is not sufficient to adequately describe specifications of higher molecular weight peptides and polypeptides, and biotechnological/biological products. The ICH Guideline Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products addresses guideline specifications, tests and procedures for biotechnological/biological products. Radiopharmaceuticals, products of fermentation, oligonucleotides, herbal products and crude products of animal or plant origin are similarly not covered.

Guidance is provided with regard to acceptance criteria which should be established for all new drug substances and new drug products, i.e. universal acceptance criteria, and those that are considered specific to individual drug substances and / or dosage forms. This guideline should not be considered all encompassing. New analytical technologies, and modifications to existing technology, are continually being developed. Such technologies should be used when justified.

Dosage forms addressed in this guideline include solid oral dosage forms, liquid oral dosage forms, and parenterals (small and large volume). This is not meant to be an all-inclusive list, or to limit the number of dosage forms to which this guideline applies. The dosage forms presented serve as models, which may be applicable to other dosage forms which have not been discussed. The extended application of the concepts in this guideline to other dosage forms, e.g., to inhalation dosage forms (powders, solutions, etc.), to topical formulations (creams, ointments, gels), and to transdermal systems, is encouraged.

2. General Concepts

The following concepts are important in the development and setting of harmonized specifications. They are not universally applicable, but each should be considered in particular circumstances. This guideline presents a brief definition of each concept and an indication of the circumstances under which it may be applicable. Generally, proposals to implement these concepts should be justified by the applicant and approved by the appropriate regulatory authority before being put into effect.

2.1 Periodic or Skip Testing

Periodic or skip testing is the performance of specified tests at release on pre-selected batches and / or at predetermined intervals, rather than on a batch-to-batch basis with the understanding that those batches not being tested still must meet all acceptance criteria established for that product. This represents a less than full schedule of testing and should therefore be justified and presented to and approved by the regulatory authority prior to implementation. This concept may be applicable to, for example, residual solvents and microbiological testing, for solid oral dosage forms. It is recognized that only limited data may be available at the time of submission of an application (see section 2.5). This concept should therefore generally be implemented post-approval. When tested, any failure to meet acceptance criteria established for the periodic test should be handled by proper notification of the appropriate regulatory authority(ies). If these data demonstrate a need to restore routine testing, then batch by batch release testing should be reinstated.

2.2 Release vs. Shelf-life Acceptance Criteria

The concept of different acceptance criteria for release vs. shelf-life specifications applies to drug products only; it pertains to the establishment of more restrictive criteria for the release of a drug product than are applied to the shelf-life. Examples where this may be applicable include assay and impurity (degradation product) levels. In Japan and the United States, this concept may only be applicable to in-house criteria, and not to the regulatory release criteria. Thus, in these regions, the regulatory acceptance criteria are the same from release throughout shelf-life; however, an applicant may choose to have tighter in-house limits at the time of release to provide increased assurance to the applicant that the product will remain within the regulatory acceptance criterion throughout its shelf-life. In the European Union there is a regulatory requirement for distinct specifications for release and for shelf-life where different.

2.3 In-process Tests

In-process tests, as presented in this guideline, are tests which may be performed during the manufacture of either the drug substance or drug product, rather than as part of the formal battery of tests which are conducted prior to release.

In-process tests which are only used for the purpose of adjusting process parameters within an operating range, e.g., hardness and friability of tablet cores which will be coated and individual tablet weights, are not included in the specification.

Certain tests conducted during the manufacturing process, where the acceptance criterion is identical to or tighter than the release requirement, (e.g., pH of a solution) may be sufficient to satisfy specification requirements when the test is included in the specification. However, this approach should be validated to show that test results or product performance characteristics do not change from the in-process stage to finished product.

2.4 Design and Development Considerations

The experience and data accumulated during the development of a new drug substance or product should form the basis for the setting of specifications. It may be possible to propose excluding or replacing certain tests on this basis. Some examples are:

  • microbiological testing for drug substances and solid dosage forms which have been shown during development not to support microbial viability or growth (see Decision Trees #6 and #8);
  • extractables from product containers where it has been reproducibly shown that either no extractables are found in the drug product or the levels meet accepted standards for safety;
  • particle size testing may fall into this category, may be performed as an in-process test, or may be performed as a release test, depending on its relevance to product performance;
  • dissolution testing for immediate release solid oral drug products made from highly water soluble drug substances may be replaced by disintegration testing, if these products have been demonstrated during development to have consistently rapid drug release characteristics (see Decision Trees #7(1) through #7(2)).

2.5 Limited Data Available at Filing

It is recognized that only a limited amount of data may be available at the time of filing, which can influence the process of setting acceptance criteria. As a result it may be necessary to propose revised acceptance criteria as additional experience is gained with the manufacture of a particular drug substance or drug product (example: acceptance limits for a specific impurity). The basis for the acceptance criteria at the time of filing should necessarily focus on safety and efficacy.

When only limited data are available, the initially approved tests and acceptance criteria should be reviewed as more information is collected, with a view towards possible modification. This could involve loosening, as well as tightening, acceptance criteria as appropriate.

2.6 Parametric Release

Parametric release can be used as an operational alternative to routine release testing for the drug product in certain cases when approved by the regulatory authority. Sterility testing for terminally sterilized drug products is one example. In this case, the release of each batch is based on satisfactory results from monitoring specific parameters, e.g., temperature, pressure, and time during the terminal sterilization phase(s) of drug product manufacturing. These parameters can generally be more accurately controlled and measured, so that they are more reliable in predicting sterility assurance than is end-product sterility testing. Appropriate laboratory tests (e.g., chemical or physical indicator) may be included in the parametric release program. It is important to note that the sterilization process should be adequately validated before parametric release is proposed and maintenance of a validated state should be demonstrated by revalidation at established intervals. When parametric release is performed, the attribute which is indirectly controlled (e.g., sterility), together with a reference to the associated test procedure, still should be included in the specifications.

2.7 Alternative Procedures

Alternative procedures are those which may be used to measure an attribute when such procedures control the quality of the drug substance or drug product to an extent that is comparable or superior to the official procedure. Example: for tablets that have been shown not to degrade during manufacture, it may be permissible to use a spectrophotometric procedure for release as opposed to the official procedure, which is chromatographic. However, the chromatographic procedure should still be used to demonstrate compliance with the acceptance criteria during the shelf-life of the product.

2.8 Pharmacopoeial Tests and Acceptance Criteria

References to certain procedures are found in pharmacopoeias in each region. Wherever they are appropriate, pharmacopoeial procedures should be utilized. Whereas differences in pharmacopoeial procedures and/or acceptance criteria have existed among the regions, a harmonized specification is possible only if the procedures and acceptance criteria defined are acceptable to regulatory authorities in all regions.

The full utility of this Guideline is dependent on the successful completion of harmonization of pharmacopoeial procedures for several attributes commonly considered in the specification for new drug substances or new drug products. The Pharmacopoeial Discussion Group (PDG) of the European Pharmacopoeia, the Japanese Pharmacopoeia, and the United States Pharmacopeia has expressed a commitment to achieving harmonization of the procedures in a timely fashion.

Where harmonization has been achieved, an appropriate reference to the harmonized procedure and acceptance criteria is considered acceptable for a specification in all three regions. For example, after harmonization sterility data generated using the JP procedure, as well as the JP procedure itself and its acceptance criteria, are considered acceptable for registration in all three regions. To signify the harmonized status of these procedures, the pharmacopoeias have agreed to include a statement in their respective texts which indicates that the procedures and acceptance criteria from all three pharmacopoeias are considered equivalent and are, therefore, interchangeable.

Since the overall value of this Guideline is linked to the extent of harmonization of the analytical procedures and acceptance criteria of the pharmacopoeias, it is agreed by the members of the Q6A expert working group that none of the three pharmacopoeias should change a harmonized monograph unilaterally. According to the PDG procedure for the revision of harmonized monographs and chapters, "no pharmacopoeia shall revise unilaterally any monograph or chapter after sign-off or after publication."

2.9 Evolving Technologies

New analytical technologies, and modifications to existing technology, are continually being developed. Such technologies should be used when they are considered to offer additional assurance of quality, or are otherwise justified.

2.10 Impact of Drug Substance on Drug Product Specifications

In general, it should not be necessary to test the drug product for quality attributes uniquely associated with the drug substance. Example: it is normally not considered necessary to test the drug product for synthesis impurities which are controlled in the drug substance and are not degradation products. Refer to the ICH Guideline Impurities in New Drug Products for detailed information.

2.11 Reference Standard

A reference standard, or reference material, is a substance prepared for use as the standard in an assay, identification, or purity test. It should have a quality appropriate to its use. It is often characterized and evaluated for its intended purpose by additional procedures other than those used in routine testing. For new drug substance reference standards intended for use in assays, the impurities should be adequately identified and / or controlled, and purity should be measured by a quantitative procedure.

3. Guidelines

3.1 Specifications: Definition and Justification

3.1.1 Definition of Specifications

A specification is defined as a list of tests, references to analytical procedures, and appropriate acceptance criteria which are numerical limits, ranges, or other criteria for the tests described. It establishes the set of criteria to which a new drug substance or new drug product should conform to be considered acceptable for its intended use. "Conformance to specifications" means that the drug substance and / or drug product, when tested according to the listed analytical procedures, will meet the listed acceptance criteria. Specifications are critical quality standards that are proposed and justified by the manufacturer and approved by regulatory authorities as conditions of approval.

It is possible that, in addition to release tests, a specification may list in-process tests as defined in 2.3, periodic (skip) tests, and other tests which are not always conducted on a batch-by-batch basis. In such cases the applicant should specify which tests are routinely conducted batch-by-batch, and which tests are not, with an indication and justification of the actual testing frequency. In this situation, the drug substance and / or drug product should meet the acceptance criteria if tested.

It should be noted that changes in the specification after approval of the application may need prior approval by the regulatory authority.

3.1.2 Justification of Specifications

When a specification is first proposed, justification should be presented for each procedure and each acceptance criterion included. The justification should refer to relevant development data, pharmacopoeial standards, test data for drug substances and drug products used in toxicology and clinical studies, and results from accelerated and long term stability studies, as appropriate. Additionally, a reasonable range of expected analytical and manufacturing variability should be considered. It is important to consider all of this information.

Approaches other than those set forth in this guideline may be applicable and acceptable. The applicant should justify alternative approaches. Such justification should be based on data derived from the new drug substance synthesis and/or the new drug product manufacturing process. This justification may consider theoretical tolerances for a given procedure or acceptance criterion, but the actual results obtained should form the primary basis for whatever approach is taken.

Test results from stability and scale-up / validation batches, with emphasis on the primary stability batches, should be considered in setting and justifying specifications. If multiple manufacturing sites are planned, it may be valuable to consider data from these sites in establishing the initial tests and acceptance criteria. This is particularly true when there is limited initial experience with the manufacture of the drug substance or drug product at any particular site. If data from a single representative manufacturing site are used in setting tests and acceptance criteria, product manufactured at all sites should still comply with these criteria.

Presentation of test results in graphic format may be helpful in justifying individual acceptance criteria, particularly for assay values and impurity levels. Data from development work should be included in such a presentation, along with stability data available for new drug substance or new drug product batches manufactured by the proposed commercial processes. Justification for proposing exclusion of a test from the specification should be based on development data and on process validation data (where appropriate).

3.2 Universal Tests / Criteria

Implementation of the recommendations in the following section should take into account the ICH Guidelines "Text on Validation of Analytical Procedures" and "Validation of Analytical Procedures: Methodology".

3.2.1 New Drug Substances

The following tests and acceptance criteria are considered generally applicable to all new drug substances.

  1. Description: a qualitative statement about the state (e.g. solid, liquid) and color of the new drug substance. If any of these characteristics change during storage, this change should be investigated and appropriate action taken.
  2. Identification: identification testing should optimally be able to discriminate between compounds of closely related structure which are likely to be present. Identification tests should be specific for the new drug substance, e.g., infrared spectroscopy. Identification solely by a single chromatographic retention time, for example, is not regarded as being specific. However, the use of two chromatographic procedures, where the separation is based on different principles or a combination of tests into a single procedure, such as HPLC/UV diode array, HPLC/MS, or GC/MS is generally acceptable. If the new drug substance is a salt, identification testing should be specific for the individual ions. An identification test that is specific for the salt itself should suffice.

    New drug substances which are optically active may also need specific identification testing or performance of a chiral assay. Please refer to 3.3.1.d) in this Guideline for further discussion of this topic.

  3. Assay: A specific, stability-indicating procedure should be included to determine the content of the new drug substance. In many cases it is possible to employ the same procedure (e.g., HPLC) for both assay of the new drug substance and quantitation of impurities.

    In cases where use of a non-specific assay is justified, other supporting analytical procedures should be used to achieve overall specificity. For example, where titration is adopted to assay the drug substance, the combination of the assay and a suitable test for impurities should be used.

  4.  Impurities: Organic and inorganic impurities and residual solvents are included in this category. Refer to the ICH Guidelines Impurities in New Drug Substances and Residual Solvents in Pharmaceuticals for detailed information.

    Decision tree #1 addresses the extrapolation of meaningful limits on impurities from the body of data generated during development. At the time of filing it is unlikely that sufficient data will be available to assess process consistency. Therefore it is considered inappropriate to establish acceptance criteria which tightly encompass the batch data at the time of filing. (see section 2.5)

3.2.2 New Drug Products

The following tests and acceptance criteria are considered generally applicable to all new drug products:

  1. Description: A qualitative description of the dosage form should be provided (e.g., size, shape, and color). If any of these characteristics change during manufacture or storage, this change should be investigated and appropriate action taken. The acceptance criteria should include the final acceptable appearance. If color changes during storage, a quantitative procedure may be appropriate.
  2. Identification: Identification testing should establish the identity of the new drug substance(s) in the new drug product and should be able to discriminate between compounds of closely related structure which are likely to be present. Identity tests should be specific for the new drug substance, e.g., infrared spectroscopy. Identification solely by a single chromatographic retention time, for example, is not regarded as being specific. However, the use of two chromatographic procedures, where the separation is based on different principles, or combination of tests into a single procedure, such as HPLC/UV diode array, HPLC/MS, or GC/MS, is generally acceptable.
  3. Assay: A specific, stability-indicating assay to determine strength (content) should be included for all new drug products. In many cases it is possible to employ the same procedure (e.g., HPLC) for both assay of the new drug substance and quantitation of impurities. Results of content uniformity testing for new drug products can be used for quantitation of drug product strength, if the methods used for content uniformity are also appropriate as assays.

    In cases where use of a non-specific assay is justified, other supporting analytical procedures should be used to achieve overall specificity. For example, where titration is adopted to assay the drug substance for release, the combination of the assay and a suitable test for impurities can be used. A specific procedure should be used when there is evidence of excipient interference with the non-specific assay.

  4. Impurities: Organic and inorganic impurities (degradation products) and residual solvents are included in this category. Refer to the ICH Guidelines Impurities in New Drug Products and Residual Solvents for detailed information.

    Organic impurities arising from degradation of the new drug substance and impurities that arise during the manufacturing process for the drug product should be monitored in the new drug product. Acceptance limits should be stated for individual specified degradation products, which may include both identified and unidentified degradation products as appropriate, and total degradation products. Process impurities from the new drug substance synthesis are normally controlled during drug substance testing, and therefore are not included in the total impurities limit. However, when a synthesis impurity is also a degradation product, its level should be monitored and included in the total degradation product limit. When it has been conclusively demonstrated via appropriate analytical methodology, that the drug substance does not degrade in the specific formulation, and under the specific storage conditions proposed in the new drug application, degradation product testing may be reduced or eliminated upon approval by the regulatory authorities.

    Decision tree #2 addresses the extrapolation of meaningful limits on degradation products from the body of data generated during development. At the time of filing it is unlikely that sufficient data will be available to assess process consistency. Therefore it is considered inappropriate to establish acceptance criteria which tightly encompass the batch data at the time of filing. (see section 2.5)

3.3 Specific Tests / Criteria

In addition to the universal tests listed above, the following tests may be considered on a case by case basis for drug substances and/or drug products. Individual tests/criteria should be included in the specification when the tests have an impact on the quality of the drug substance and drug product for batch control. Tests other than those listed below may be needed in particular situations or as new information becomes available.

3.3.1 New Drug Substances

  1. Physicochemical properties: These are properties such as pH of an aqueous solution, melting point / range, and refractive index. The procedures used for the measurement of these properties are usually unique and do not need much elaboration, e.g., capillary melting point, Abbé refractometry. The tests performed in this category should be determined by the physical nature of the new drug substance and by its intended use.
  2. Particle size: For some new drug substances intended for use in solid or suspension drug products, particle size can have a significant effect on dissolution rates, bioavailability, and / or stability. In such instances, testing for particle size distribution should be carried out using an appropriate procedure, and acceptance criteria should be provided.

    Decision tree #3 provides additional guidance on when particle size testing should be considered.

  3. Polymorphic forms: Some new drug substances exist in different crystalline forms which differ in their physical properties. Polymorphism may also include solvation or hydration products (also known as pseudopolymorphs) and amorphous forms. Differences in these forms could, in some cases, affect the quality or performance of the new drug products. In cases where differences exist which have been shown to affect drug product performance, bioavailability or stability, then the appropriate solid state should be specified.

    Physicochemical measurements and techniques are commonly used to determine whether multiple forms exist. Examples of these procedures are: melting point (including hot-stage microscopy), solid state IR, X-ray powder diffraction, thermal analysis procedures (like DSC, TGA and DTA), Raman spectroscopy, optical microscopy, and solid state NMR.

    Decision trees #4(1) through 4(3) provide additional guidance on when, and how, polymorphic forms should be monitored and controlled.

    Note: These decision trees should be followed sequentially. Trees 1 and 2 consider whether polymorphism is exhibited by the drug substance, and whether the different polymorphic forms can affect performance of the drug product. Tree 3 should only be applied when polymorphism has been demonstrated for the drug substance, and shown to affect these properties. Tree 3 considers the potential for change in polymorphic forms in the drug product, and whether such a change has any effect on product performance.

    It is generally technically very difficult to measure polymorphic changes in drug products. A surrogate test (e.g., dissolution) (see Decision tree 4(3)) can generally be used to monitor product performance, and polymorph content should only be used as a test and acceptance criterion of last resort.

  4. Tests for chiral new drug substances: Where a new drug substance is predominantly one enantiomer, the opposite enantiomer is excluded from the qualification and identification thresholds given in the ICH Guidelines on Impurities in New Drug Substances and Impurities in New Drug Products because of practical difficulties in quantifying it at those levels. However, that impurity in the chiral new drug substance and the resulting new drug product(s) should otherwise be treated according to the principles established in those Guidelines.

    Decision tree #5 summarizes when and if chiral identity tests, impurity tests, and assays may be needed for both new drug substances and new drug products, according to the following concepts:

    Drug Substance: Impurities. For chiral drug substances which are developed as a single enantiomer, control of the other enantiomer should be considered in the same manner as for other impurities. However, technical limitations may preclude the same limits of quantification or qualification from being applied. Assurance of control also could be given by appropriate testing of a starting material or intermediate, with suitable justification.

    Assay: An enantioselective determination of the drug substance should be part of the specification. It is considered acceptable for this to be achieved either through use of a chiral assay procedure or by the combination of an achiral assay together with appropriate methods of controlling the enantiomeric impurity.

    Identity: For a drug substance developed as a single enantiomer, the identity test(s) should be capable of distinguishing both enantiomers and the racemic mixture. For a racemic drug substance, there are generally two situations where a stereospecific identity test is appropriate for release/acceptance testing: 1) where there is a significant possibility that the enantiomer might be substituted for the racemate, or 2) when there is evidence that preferential crystallization may lead to unintentional production of a non-racemic mixture.

    Drug Product: Degradation products. Control of the other enantiomer in a drug product is considered necessary unless racemization has been shown to be insignificant during manufacture of the dosage form, and on storage.

    Assay: An achiral assay may be sufficient where racemization has been shown to be insignificant during manufacture of the dosage form, and on storage. Otherwise a chiral assay should be used, or alternatively, the combination of an achiral assay plus a validated procedure to control the presence of the opposite enantiomer may be used.

    Identity: A stereospecific identity test is not generally needed in the drug product release specification. When racemization is insignificant during manufacture of the dosage form, and on storage, stereospecific identity testing is more appropriately addressed as part of the drug substance specification. When racemization in the dosage form is a concern, chiral assay or enantiomeric impurity testing of the drug product will serve to verify identity.

  5. Water content: This test is important in cases where the new drug substance is known to be hygroscopic or degraded by moisture or when the drug substance is known to be a stoichiometric hydrate. The acceptance criteria may be justified with data on the effects of hydration or moisture absorption. In some cases, a Loss on Drying procedure may be considered adequate; however, a detection procedure that is specific for water (e.g., Karl Fischer titration) is preferred.
  6. Inorganic impurities: The need for inclusion of tests and acceptance criteria for inorganic impurities (e.g., catalysts) should be studied during development and based on knowledge of the manufacturing process. Procedures and acceptance criteria for sulfated ash / residue on ignition should follow pharmacopoeial precedents; other inorganic impurities may be determined by other appropriate procedures, e.g., atomic absorption spectroscopy.
  7. Microbial limits: There may be a need to specify the total count of aerobic microorganisms, the total count of yeasts and molds, and the absence of specific objectionable bacteria (e.g., Staphylococcus aureus, Escherichia coli, Salmonella, Pseudomonas aeruginosa). These should be suitably determined using pharmacopoeial procedures. The type of microbial test(s) and acceptance criteria should be based on the nature of the drug substance, method of manufacture, and the intended use of the drug product. For example, sterility testing may be appropriate for drug substances manufactured as sterile and endotoxin testing may be appropriate for drug substances used to formulate an injectable drug product.

    Decision tree #6 provides additional guidance on when microbial limits should be included.

3.3.2 New Drug Products

Additional tests and acceptance criteria generally should be included for particular new drug products. The following selection presents a representative sample of both the drug products and the types of tests and acceptance criteria which may be appropriate. The specific dosage forms addressed include solid oral drug products, liquid oral drug products, and parenterals (small and large volume). Application of the concepts in this guideline to other dosage forms is encouraged. Note that issues related to optically active drug substances and to solid state considerations for drug products are discussed in part 3.3.1. of this guideline.

3.3.2.1 The following tests are applicable to tablets (coated and uncoated) and hard capsules. One or more of these tests may also be applicable to soft capsules and granules.

  1. Dissolution: The specification for solid oral dosage forms normally includes a test to measure release of drug substance from the drug product. Single-point measurements are normally considered to be suitable for immediate-release dosage forms. For modified-release dosage forms, appropriate test conditions and sampling procedures should be established. For example, multiple time point sampling should be performed for extended-release dosage forms, and two-stage testing (using different media in succession or in parallel, as appropriate) may be appropriate for delayed-release dosage forms. In these cases it is important to consider the populations of individuals who will be taking the drug product (e.g., achlorhydric elderly) when designing the tests and acceptance criteria. In some cases (see 3.3.2.1 b) Disintegration) dissolution testing may be replaced by disintegration testing (see Decision Tree #7 (1)).

    For immediate-release drug products where changes in dissolution rate have been demonstrated to significantly affect bioavailability, it is desirable to develop test conditions which can distinguish batches with unacceptable bioavailability. If changes in formulation or process variables significantly affect dissolution and such changes are not controlled by another aspect of the specification, it may also be appropriate to adopt dissolution test conditions which can distinguish these changes (see Decision Tree #7(2)).

    Where dissolution significantly affects bioavailability, the acceptance criteria should be set to reject batches with unacceptable bioavailability. Otherwise, test conditions and acceptance criteria should be established which pass clinically acceptable batches (see Decision Tree #7(2)).

    For extended-release drug products, in vitro / in vivo correlation may be used to establish acceptance criteria when human bioavailability data are available for formulations exhibiting different release rates. Where such data are not available, and drug release cannot be shown to be independent of in vitro test conditions, then acceptance criteria should be established on the basis of available batch data. Normally, the permitted variability in mean release rate at any given time point should not exceed a total numerical difference of /-10% of the labeled content of drug substance (i.e., a total variability of 20%: a requirement of 50 /- 10% thus means an acceptable range from 40% to 60%), unless a wider range is supported by a bioequivalency study (see Decision Tree #7(3)).

  2. Disintegration: For rapidly dissolving (dissolution >80% in 15 minutes at pH 1.2, 4.0 and 6.8) products containing drugs which are highly soluble throughout the physiological range (dose/solubility volume < 250 mL from pH 1.2 to 6.8), disintegration may be substituted for dissolution. Disintegration testing is most appropriate when a relationship to dissolution has been established or when disintegration is shown to be more discriminating than dissolution. In such cases dissolution testing may not be necessary. It is expected that development information will be provided to support the robustness of the formulation and manufacturing process with respect to the selection of dissolution vs. disintegration testing (see Decision Tree #7(1)).
  3. Hardness/friability: It is normally appropriate to perform hardness and/or friability testing as an in-process control (see section 2.3). Under these circumstances, it is normally not necessary to include these attributes in the specification. If the characteristics of hardness and friability have a critical impact on drug product quality (e.g., chewable tablets), acceptance criteria should be included in the specification.
  4. Uniformity of dosage units: This term includes both the mass of the dosage form and the content of the active substance in the dosage form; a pharmacopoeial procedure should be used. In general, the specification should include one or the other but not both. If appropriate, these tests may be performed in-process; the acceptance criteria should be included in the specification. When weight variation is applied for new drug products exceeding the threshold value to allow testing uniformity by weight variation, applicants should verify during drug development that the homogeneity of the product is adequate.
  5. Water content: A test for water content should be included when appropriate. The acceptance criteria may be justified with data on the effects of hydration or water absorption on the drug product. In some cases, a Loss on Drying procedure may be considered adequate; however, a detection procedure which is specific for water (e.g., Karl Fischer titration) is preferred.
  6. Microbial limits: Microbial limit testing is seen as an attribute of Good Manufacturing Practice, as well as of quality assurance. In general, it is advisable to test the drug product unless its components are tested before manufacture and the manufacturing process is known, through validation studies, not to carry a significant risk of microbial contamination or proliferation. It should be noted that, whereas this guideline does not directly address excipients, the principles discussed here may be applicable to excipients as well as to new drug products. Skip testing may be an appropriate approach in both cases where permissible. (See Decision Tree #6 for microbial testing of excipients.)

    Acceptance criteria should be set for the total count of aerobic microorganisms, the total count of yeasts and molds, and the absence of specific objectionable bacteria (e.g., Staphylococcus aureus, Escherichia coli, Salmonella, Pseudomonas aeruginosa). These should be determined by suitable procedures, using pharmacopoeial procedures, and at a sampling frequency or time point in manufacture which is justified by data and experience. The type of microbial test(s) and acceptance criteria should be based on the nature of the drug substance, method of manufacture, and the intended use of the drug product. With acceptable scientific justification, it should be possible to propose no microbial limit testing for solid oral dosage forms.

    Decision tree #8 provides additional guidance on the use of microbial limits testing.

3.3.2.2 Oral liquids:

One or more of the following specific tests will normally be applicable to oral liquids and to powders intended for reconstitution as oral liquids.

  1. Uniformity of dosage units: This term includes both the mass of the dosage form and the content of the active substance in the dosage form; a pharmacopoeial procedure should be used. In general, the specification should include one or the other but not both. When weight variation is applied for new drug products exceeding the threshold value to allow testing uniformity by weight variation, applicants should verify during drug development that the homogeneity of the product is adequate.

    If appropriate, tests may be performed in-process; however, the acceptance criteria should be included in the specification. This concept may be applied to both single-dose and multiple-dose packages.

    The dosage unit is considered to be the typical dose taken by the patient. If the actual unit dose, as taken by the patient, is controlled, it may either be measured directly or calculated, based on the total measured weight or volume of drug divided by the total number of doses expected. If dispensing equipment (such as medicine droppers or dropper tips for bottles) is an integral part of the packaging, this equipment should be used to measure the dose. Otherwise, a standard volume measure should be used. The dispensing equipment to be used is normally determined during development.

    For powders for reconstitution, uniformity of mass testing is generally considered acceptable.

  2. pH: Acceptance criteria for pH should be provided where applicable and the proposed range justified.
  3. Microbial limits: Microbial limit testing is seen as an attribute of Good Manufacturing Practice, as well as of quality assurance. In general, it is advisable to test the drug product unless its components are tested before manufacture and the manufacturing process is known, through validation studies, not to carry a significant risk of microbial contamination or proliferation. It should be noted that, whereas this Guideline does not directly address excipients, the principles discussed here may be applicable to excipients as well as to new drug products. Skip testing may be an appropriate approach in both cases where permissible. With acceptable scientific justification, it may be possible to propose no microbial limit testing for powders intended for reconstitution as oral liquids.

    Acceptance criteria should be set for the total count of aerobic microorganisms, total count of yeasts and molds, and the absence of specific objectionable bacteria (e.g., Staphylococcus aureus, Escherichia coli, Salmonella, Pseudomonas aeruginosa). These should be determined by suitable procedures, using pharmacopoeial procedures, and at a sampling frequency or time point in manufacture which is justified by data and experience.

    Decision tree #8 provides additional guidance on the use of microbial limits testing.

  4. Antimicrobial preservative content: For oral liquids needing an antimicrobial preservative, acceptance criteria for preservative content should be established. Acceptance criteria for preservative content should be based upon the levels of antimicrobial preservative necessary to maintain microbiological quality of the product at all stages throughout its proposed usage and shelf-life. The lowest specified concentration of antimicrobial preservative should be demonstrated to be effective in controlling microorganisms by using a pharmacopoeial antimicrobial preservative effectiveness test.

    Testing for antimicrobial preservative content should normally be performed at release. Under certain circumstances, in-process testing may suffice in lieu of release testing. When antimicrobial preservative content testing is performed as an in-process test, the acceptance criteria should remain part of the specification.

    Antimicrobial preservative effectiveness should be demonstrated during development, during scaleup, and throughout the shelf-life (e.g., in stability testing: see the ICH Guideline, "Stability Testing of New Drug Substances and Products"), although chemical testing for preservative content is the attribute normally included in the specification.

  5. Antioxidant preservative content: Release testing for antioxidant content should normally be performed. Under certain circumstances, where justified by developmental and stability data, shelf-life testing may be unnecessary, and in-process testing may suffice in lieu of release testing where permitted. When antioxidant content testing is performed as an in-process test, the acceptance criteria should remain part of the specification. If only release testing is performed, this decision should be reinvestigated whenever either the manufacturing procedure or the container/closure system changes.
  6. Extractables: Generally, where development and stability data show evidence that extractables from the container/closure systems are consistently below levels that are demonstrated to be acceptable and safe, elimination of this test can normally be accepted. This should be reinvestigated if the container/closure system or formulation changes.

    Where data demonstrate the need, tests and acceptance criteria for extractables from the container/closure system components (e.g., rubber stopper, cap liner, plastic bottle, etc.) are considered appropriate for oral solutions packaged in non-glass systems, or in glass containers with non-glass closures. The container/closure components should be listed, and data collected for these components as early in the development process as possible.

  7. Alcohol content: Where it is declared quantitatively on the label in accordance with pertinent regulations, the alcohol content should be specified. It may be assayed or calculated.
  8. Dissolution: In addition to the attributes recommended immediately above, it may be appropriate (e.g., insoluble drug substance) to include dissolution testing and acceptance criteria for oral suspensions and dry powder products for resuspension. Dissolution testing should be performed at release. This test may be performed as an in-process test when justified by product development data. The testing apparatus, media, and conditions should be pharmacopoeial, if possible, or otherwise justified. Dissolution procedures using either pharmacopoeial or non-pharmacopoeial apparatus and conditions should be validated.

    Single-point measurements are normally considered suitable for immediate-release dosage forms. Multiple-point sampling, at appropriate intervals, should be performed for modified-release dosage forms. Acceptance criteria should be set based on the observed range of variation, and should take into account the dissolution profiles of the batches that showed acceptable performance in vivo. Developmental data should be considered when determining the need for either a dissolution procedure or a particle size distribution procedure.

  9. Particle size distribution: Quantitative acceptance criteria and a procedure for determination of particle size distribution may be appropriate for oral suspensions. Developmental data should be considered when determining the need for either a dissolution procedure or a particle size distribution procedure for these formulations.

    Particle size distribution testing should be performed at release. It may be performed as an in-process test when justified by product development data. If these products have been demonstrated during development to have consistently rapid drug release characteristics, exclusion of a particle size distribution test from the specification may be proposed.

    Particle size distribution testing may also be proposed in place of dissolution testing; justification should be provided. The acceptance criteria should include acceptable particle size distribution in terms of the percent of total particles in given size ranges. The mean, upper, and / or lower particle size limits should be well defined.

    Acceptance criteria should be set based on the observed range of variation, and should take into account the dissolution profiles of the batches that showed acceptable performance in vivo, as well as the intended use of the product. The potential for particle growth should be investigated during product development; the acceptance criteria should take the results of these studies into account.

  10. Redispersibility: For oral suspensions which settle on storage (produce sediment), acceptance criteria for redispersibility may be appropriate. Shaking may be an appropriate procedure.

    The procedure (mechanical or manual) should be indicated. Time required to achieve resuspension by the indicated procedure should be clearly defined. Data generated during product development may be sufficient to justify skip lot testing, or elimination of this attribute from the specification may be proposed.

  11. Rheological properties: For relatively viscous solutions or suspensions, it may be appropriate to include rheological properties (viscosity/specific gravity) in the specification. The test and acceptance criteria should be stated. Data generated during product development may be sufficient to justify skip lot testing, or elimination of this attribute from the specification may be proposed.
  12. Reconstitution time: Acceptance criteria for reconstitution time should be provided for dry powder products which require reconstitution. The choice of diluent should be justified. Data generated during product development may be sufficient to justify skip lot testing or elimination of this attribute from the specification may be proposed.
  13. Water content: For oral products requiring reconstitution, a test and acceptance criterion for water content should be proposed when appropriate. Loss on drying is generally considered sufficient if the effect of absorbed moisture vs. water of hydration has been adequately characterized during the development of the product. In certain cases a more specific procedure (e.g., Karl Fischer titration) may be preferable.

3.3.2.3 Parenteral Drug Products: The following tests may be applicable to parenteral drug products.

  1. Uniformity of dosage units: This term includes both the mass of the dosage form and the content of the active substance in the dosage form; a pharmacopoeial procedure should be used. In general, the specification should one or the other but not both and is applicable to powders for reconstitution. When weight variation is applied for new drug products exceeding the threshold value to allow testing uniformity by weight variation, applicants should verify during drug development that the homogeneity of the product is adequate.

    If appropriate (see section 2.3), these tests may be performed in-process; the acceptance criteria should be included in the specification. This test may be applied to both single-dose and multiple-dose packages.

    For powders for reconstitution, uniformity of mass testing is generally considered acceptable.

  2. b) pH: Acceptance criteria for pH should be provided where applicable and the proposed range justified.
  3. Sterility: All parenteral products should have a test procedure and acceptance criterion for evaluation of sterility. Where data generated during development and validation justify parametric release, this approach may be proposed for terminally sterilized drug products (see section 2.6).
  4. Endotoxins/Pyrogens: A test procedure and acceptance criterion for endotoxins, using a procedure such as the limulus amoebocyte lysate test, should be included in the specification. Pyrogenicity testing may be proposed as an alternative to endotoxin testing where justified.
  5. Particulate matter: Parenteral products should have appropriate acceptance criteria for particulate matter. This will normally include acceptance criteria for visible particulates and / or clarity of solution, as well as for sub-visible particulates as appropriate.
  6. Water content: For non-aqueous parenterals, and for parenteral products for reconstitution, a test procedure and acceptance criterion for water content should be proposed when appropriate. Loss on drying is generally considered sufficient for parenteral products, if the effect of absorbed moisture vs. water of hydration has been adequately characterized during development. In certain cases a more specific procedure (e.g., Karl Fischer titration) may be preferred.
  7. Antimicrobial preservative content: For parenteral products needing an antimicrobial preservative, acceptance criteria for preservative content should be established. Acceptance criteria for preservative content should be based upon the levels of antimicrobial preservative necessary to maintain microbiological quality of the product at all stages throughout its proposed usage and shelf life. The lowest specified concentration of antimicrobial preservative should be demonstrated to be effective in controlling microorganisms by using a pharmacopoeial antimicrobial preservative effectiveness test.

    Testing for antimicrobial preservative content should normally be performed at release. Under certain circumstances, in-process testing may suffice in lieu of release testing where permitted. When antimicrobial preservative content testing is performed as an in-process test, the acceptance criteria should remain part of the specification.

    Antimicrobial preservative effectiveness should be demonstrated during development, during scaleup, and throughout the shelf-life (e.g., in stability testing: see the ICH Guideline, "Stability Testing of New Drug Substances and Products"), although chemical testing for preservative content is the attribute normally included in the specification.

  8. Antioxidant preservative content: Release testing for antioxidant content should normally be performed. Under certain circumstances, where justified by developmental and stability data, shelf-life testing may be unnecessary and in-process testing may suffice in lieu of release testing. When antioxidant content testing is performed as an in-process test, the acceptance criteria should remain part of the specification. If only release testing is performed, this decision should be reinvestigated whenever either the manufacturing procedure or the container/closure system changes.
  9. i) Extractables: Control of extractables from container/closure systems is considered significantly more important for parenteral products than for oral liquids. However, where development and stability data show evidence that extractables are consistently below the levels that are demonstrated to be acceptable and safe, elimination of this test can normally be accepted. This should be reinvestigated if the container/closure system or formulation changes.

    Where data demonstrate the need, acceptance criteria for extractables from the container/closure components are considered appropriate for parenteral products packaged in non-glass systems or in glass containers with elastomeric closures. This testing may be performed at release only, where justified by data obtained during development. The container/closure system components (e.g., rubber stopper, etc.) should be listed, and data collected for these components as early in the development process as possible.

  10. Functionality testing of delivery systems: Parenteral formulations packaged in pre-filled syringes, autoinjector cartridges, or the equivalent should have test procedures and acceptance criteria related to the functionality of the delivery system. These may include control of syringeability, pressure, and seal integrity (leakage), and/or parameters such as tip cap removal force, piston release force, piston travel force, and power injector function force. Under certain circumstances these tests may be performed in-process. Data generated during product development may be sufficient to justify skip lot testing or elimination of some or all attributes from the specification.
  11. Osmolarity: When the tonicity of a product is declared in its labeling, appropriate control of its osmolarity should be performed. Data generated during development and validation may be sufficient to justify performance of this procedure as an in-process control, skip lot testing, or direct calculation of this attribute.
  12. l) Particle size distribution: Quantitative acceptance criteria and a procedure for determination of particle size distribution may be appropriate for injectable suspensions. Developmental data should be considered when determining the need for either a dissolution procedure or a particle size distribution procedure.

    Particle size distribution testing should be performed at release. It may be performed as an in-process test when justified by product development data. If the product has been demonstrated during development to have consistently rapid drug release characteristics, exclusion of particle size controls from the specification may be proposed.

    Particle size distribution testing may also be proposed in place of dissolution testing, when development studies demonstrate that particle size is the primary factor influencing dissolution; justification should be provided. The acceptance criteria should include acceptable particle size distribution in terms of the percent of total particles in given size ranges. The mean, upper, and / or lower particle size limits should be well defined.

    Acceptance criteria should be set based on the observed range of variation, and should take into account the dissolution profiles of the batches that showed acceptable performance in vivo and the intended use of the product. The potential for particle growth should be investigated during product development; the acceptance criteria should take the results of these studies into account.

  13. Redispersibility: For injectable suspensions which settle on storage (produce sediment), acceptance criteria for redispersibility may be appropriate. Shaking may be an appropriate procedure. The procedure (mechanical or manual) should be indicated. Time required to achieve resuspension by the indicated procedure should be clearly defined. Data generated during product development may be sufficient to justify skip lot testing, or elimination of this attribute from the specification may be proposed.
  14. Reconstitution time: Acceptance criteria for reconstitution time should be provided for all parenteral products which require reconstitution. The choice of diluent should be justified. Data generated during product development and process validation may be sufficient to justify skip lot testing or elimination of this attribute from the specification for rapidly dissolving products.

4. Glossary

(The following definitions are presented for the purpose of this Guideline)

Acceptance criteria:
Numerical limits, ranges, or other suitable measures for acceptance of the results of analytical procedures.
Chiral:
Not superimposable with its mirror image, as applied to molecules, conformations, and macroscopic objects, such as crystals. The term has been extended to samples of substances whose molecules are chiral, even if the macroscopic assembly of such molecules is racemic.
Combination product:
A drug product which contains more than one drug substance.
Degradation product:
A molecule resulting from a chemical change in the drug molecule brought about over time and/or by the action of e.g., light, temperature, pH, water, or by reaction with an excipient and/or the immediate container/closure system. Also called decomposition product.
Delayed Release:
Release of a drug (or drugs) at a time other than immediately following oral administration.
Enantiomers:
Compounds with the same molecular formula as the drug substance, which differ in the spatial arrangement of atoms within the molecule and are nonsuperimposable mirror images.
Extended Release:
Products which are formulated to make the drug available over an extended period after administration.
Highly Water Soluble Drugs:
Drugs with a dose/solubility volume of less than or equal to 250 millilitre (mL) over a pH range of 1.2 to 6.8. (Example: Compound A has as its lowest solubility at 37± 0.5°C, 1.0 milligram/millilitre (mg/mL) at pH 6.8, and is available in 100 mg, 200 mg, and 400 mg strengths. This drug would be considered a low solubility drug as its dose/solubility volume is greater than 250 mL (400 mg/1.0 mg/mL = 400 mL).
Immediate Release:
Allows the drug to dissolve in the gastrointestinal contents, with no intention of delaying or prolonging the dissolution or absorption of the drug.
Impurity:
(1) Any component of the new drug substance which is not the chemical entity defined as the new drug substance. (2) Any component of the drug product which is not the chemical entity defined as the drug substance or an excipient in the drug product.
Identified impurity:
An impurity for which a structural characterization has been achieved.
In-process tests:
Tests which may be performed during the manufacture of either the drug substance or drug product, rather than as part of the formal battery of tests which are conducted prior to release.
Modified Release:
Dosage forms whose drug-release characteristics of time course and/or location are chosen to accomplish therapeutic or convenience objectives not offered by conventional dosage forms such as a solution or an immediate release dosage form. Modified release solid oral dosage forms include both delayed and extended release drug products.
New drug product:
A pharmaceutical product type, for example, tablet, capsule, solution, cream, etc., which has not previously been registered in a region or Member State, and which contains a drug ingredient generally, but not necessarily, in association with excipients.
New drug substance:
The designated therapeutic moiety, which has not previously been registered in a region or Member State (also referred to as a new molecular entity or new chemical entity). It may be a complex, simple ester, or salt of a previously approved drug substance.
Polymorphism:
The occurrence of different crystalline forms of the same drug substance. This may include solvation or hydration products (also known as pseudopolymorphs) and amorphous forms.
Quality:
The suitability of either a drug substance or drug product for its intended use. This term includes such attributes as the identity, strength, and purity.
Racemate:
A composite (solid, liquid, gaseous, or in solution) of equimolar quantities of two enantiomeric species. It is devoid of optical activity.
Rapidly Dissolving Products:
An immediate release solid oral drug product is considered rapidly dissolving when not less than 80% of the label amount of the drug substance dissolves within 15 minutes in each of the following media: (1) pH 1.2, (2) pH 4.0, and (3) pH 6.8.
Reagent:
A substance, other than a starting material or solvent, which is used in the manufacture of a new drug substance.
Solvent:
An inorganic or an organic liquid used as a vehicle for the preparation of solutions or suspensions in the synthesis of a new drug substance or the manufacture of a new drug product.
Specification:
A list of tests, references to analytical procedures, and appropriate acceptance criteria which are numerical limits, ranges, or other criteria for the tests described. It establishes the set of criteria to which a drug substance or drug product should conform to be considered acceptable for its intended use. "Conformance to specifications" means that the drug substance and / or drug product, when tested according to the listed analytical procedures, will meet the listed acceptance criteria. Specifications are critical quality standards that are proposed and justified by the manufacturer and approved by regulatory authorities.
Specific test:
A test which is considered to be applicable to particular new drug substances or particular new drug products depending on their specific properties and/or intended use.
Specified impurity:
An identified or unidentified impurity that is selected for inclusion in the new drug substance or new drug product specification and is individually listed and limited in order to assure the quality of the new drug substance or new drug product.
Unidentified impurity:
An impurity which is defined solely by qualitative analytical properties, (e.g., chromatographic retention time).
Universal test:
A test which is considered to be potentially applicable to all new drug substances, or all new drug products; e.g., appearance, identification, assay, and impurity tests.

5. References

International Conference on Harmonisation; "Impurities in New Drug Substances", 1995.

International Conference on Harmonisation; "Impurities in New Drug Products", 1996.

International Conference on Harmonisation; "Stability Testing of New Drug Substances and Products", 1994.

International Conference on Harmonisation; "Text on Validation of Analytical Procedures", 1994.

International Conference on Harmonisation; "Validation of Analytical Procedures: Methodology", 1996.

International Conference on Harmonisation, "Residual Solvents in Pharmaceuticals", 1996.

International Conference on Harmonisation, "Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products", 1999

6. Attachments

Decision Trees #1 through #8

Decision #1: Established Acceptance Criterion for a Specified Impurity in a New Drug Substance

Rectangular box indicating "Determine impurity level in relevant batches". Downwards arrow to rectangular box indicating "Determine mean plus upper confidence limit for the impurity (Let this equal A). Right pointing arrow to a diamond shape indicating "Is impurity also a degradation of product?".

If yes: right pointing arrow to rectangular box stating "Estimate maximum increase in impurity at retest date using data from relevant accelerated and long-term stability studies" with downward arrow into rectangular box stating "Determine maximum likely level as: A + increase in degradation product at appropriate storage conditions. (Let this equal B)" with left arrow into diamond stating "Is A or B greater than the qualified level"

If no:  downward arrow into diamond stating "Is A or B greater than the qualified level"

  • If yes: downward arrow into rectangle stating "Acceptance criterion equals qualified level or establish new qualified level"
  • If no: leftward arrow into rectangle stating "Acceptance criterion = A or B (As appropriate)"

Decision #2: Established Acceptance Criterion for a Degradation Produc in a New Drug Product

Diamond indicating "Does degradation occur during product manufacture?"

If yes: downward arrow to rectangle indicating "Estimate maximum increase in degradation product during manufacture from relevant batches. (Let this = C). Then upward right arrow into rectangle indicating "Estimate maximum increase in degradation product at shelf life using data from relevant accelerated and long term stability studies. (Let this = D)."

If no: Right arrow into rectangle indicating "Estimate maximum increase in degradation product at shelf life using data from relevant accelerated and long term stability studies. (Let this = D)."

Downward arrow to rectangle indicating "Determine maximum likely level as drug substance acceptance criterion.((A or B) + C + D)."

Downward arrow into diamond indicating "Is maximum likely level greater than the qualified level?"

If yes: downward arrow to rectangle indicating "Acceptance criterion equals qualified level or establish  new qualified level or new storage conditions or reduce shelf life."

If no: left arrow into rectangle indicating "Acceptance criterion equals maximum likely level."

Decision #3: Setting Acceptance Criteria for Drug Substance Particle Size Distribution

Diamond indicating "is the drug product a solid dosage form or liquid containing undissolved drug substance?"

  • If no: Right arrow into rectangle indicating "No drug substance particle size acceptance criterion required for solution dosage forms".
  • If yes: Downward arrow into diamond indicating:
    1. Is the particle size critical to dissolution, solubility, or bioavailiability?
    2. Is the particle size critical to drug product processability?
    3. Is the particle size critical to drug product stability?
    4. Is the particle size critical to drug product content uniformity?
    5. Is the particle size critical for maintaining product appearance?"
      • If NO to all: Right downward arrow into rectangle indicating "No acceptance criterion required."
      • If YES to any: downward arrow indicating "Set acceptance criterion"

Decision #4: Investigating the Need to set Acceptance Criteria for Polymorphism in Drug Substance and Drug Products
  1. Rectangle indicating "Conduct polymorphism screen on drug substance with right arrow into diamond indicating "Can different polymorphs be formed?"
    • If no: Right arrow into rectangle indicating "No further action."
    • If yes: Downward arrow into rectangle indicating:
      • "Characterize the forms:
        • e.g., X-ray powder diffraction
        • DSC / Thermoanalysis
        • Microscopy
        • Spectroscopy
  2. Diamond indicating "Do the forms have different properties? (solubility, stability, melting point)"
    • If no: Right downward arrow into rectangle indicating "No further test or acceptance criterion for drug substance"
    • If yes: Downward arrow into diamond indicating "Is drug product safety, performance or efficacy related?"
      • If no: Right upward arrow into rectangle indicating "No further test or acceptance criterion for drug substance"
      • If yes: Downward arrow into rectangle indicating "Set acceptance criterion for polymorph content in drug substance."
      • Right arrow indicating " GO TO 3."
  3. Diamond indicating "Does drug product performance testing provide adequate control if polymorph changes (e.g. dissolution)?"
    • If yes: Right arrow into rectangle indicating "Establish acceptance criteria for the relevant performance test(s).
    • If no: Downward arrow into rectangle indicating "Monitor polymorph form during stability of drug product."
    • Downward arrow into diamond indicating "Does a change occur which could affect safety or efficacy?"
      • If no: Right arrow into rectangle indicating "No need to set acceptance criteria for polymorph change in drug product."
      • If yes: Downward arrow intro rectangle indicating "Establish acceptance criteria which are consistent with safety and/or efficacy."

Decision #5: Establishing Identity,Assay and Enanthiomeric Impuity Procedures for Chiral New Drug Substances and New Drug Products Containing Chiral Drug Substances

Diamond indicating "Is the new drug substance chiral?"

  • If yes and racemic: Left arrow into rectangle indicating "Consider the need for verifying chiral identity in drug substance release and/or acceptance testing.
  • If yes and one enantiomer: Downward arrow into rectangle indicating
    • "Needed for drug substance specification:
      • Chiral identity
      • Chiral assay
      • Enantiomeric impurity
  • Needed for drug product specification:
    • Chiral assay
    • Enantiomeric impurity"
  • If no: Right arrow into rectangle indicating "Chiral identity, assay and impurity procedures are not needed.

Decision #6: Microbiological Quality Attributes of Drug Substance Excipients

Diamond indicating "Is the drug substance/excipient capable of supporting microbial growth or viability?"

  • If no: Rightward arrow into rectangle indicating "Provide supporting data. Microbial limits acceptance criteria testing may not be necessary."
  • If yes: Downward arrow into diamond indicating "Is the drug substance/excipient sterile?"
    • If yes: Rightward arrow into rectangle indicating "No further microbial limits testing or acceptance criteria are necessary."
    • If no: Downward arrow into diamond indicating "Does drug substance/excipient synthesis/processing involve steps which inherently reduce microorganisms?"
      • If yes: Rightward arrow into rectangle indicating "Establish microbial limit acceptance criteria as per the harmonized pharmacopeia monograph.
      • Downward arrow into diamond indicating "Does scientific evidence demonstrate that reduction steps result in microorganism levels < acceptance criteria limits (and the absence of compendia indicator organisms) in the drug substance/excipient?"
        • If yes: Diagonal downward right arrow to rectangle indicating "Provide supporting data. Microbial limits acceptance criteria and testing may not be necessary."
        • If no: Downward left arrow into rectangle indicating "Test each lot for microbial limits and freedom from compendia indicator organisms."
      • If no: Downward arrow into rectangle indicating "Establish microbial limit acceptance criteria as per the harmonized pharmacopoeia monograph."
      • Downward arrow into diamond indicating "Are monitoring microorganism/indicator levels consistently below acceptance criteria levels?"
        • If yes: Diagonal downward left arrow into rectangle indicating "Test lots on a skip-lot basis for microbial limits and freedom from compendia indicator organisms."
        • If no: Diagonal downward right arrow into rectangle indicating "Test each lot for microbial limits and freedom from compendia indicator organisms."

Decision #7: Setting Acceptance Criteria for Drug Product Dissolution
  1. What type of drug release acceptance criteria are appropriate?

    Diamond indicating "Is the dosage form designed to produce modified release?"

    • If yes: Right arrow into rectangle indicating "Establish drug release acceptance criteria. Extend release: multiple time points. Delayed release: two stages, parallel or sequential."
    • If no: Downward arrow into diamond indicating "Is drug solubility at 37 +/- 0.5 degrees Celsius high throughout the physiological pH range? (Dose/solubility less than or equal to 250mL (pH 1.2-6.8))"
      • If no: Diagonal right downward arrow into rectangle indicating "Generally single-point dissolution  acceptance criteria with a lower limit are acceptable."
      • If yes: Downward arrow into diamond indicating "Is dosage dissolution rapid? (Dissolution greater than 80% in fifteen minutes at pH 1.2, 4.0, and 6.8)"
        • If no: Right arrow into rectangle indicating "Generally single-point dissolution acceptance criteria with a lower limit are acceptable."
        • If yes: Downward arrow into diamond indicating "Has a relationship been determined between disintegration and dissolution?"
          • If yes: Right arrow into rectangle indicating "Generally disintegration acceptance criteria with an upper time limit are acceptable."
          • If no: Diagonal right upward arrow into rectangle indicating "Generally single-point dissolution acceptance criteria with a lower limit are acceptable."
  2. What specific test conditions and acceptance criteria are appropriate? (immediate release)

    Diamond indicating "Does dissolution significantly affect bioavailability? (e.g. have relevant developmental batches exhibited unacceptable bioavailability?)"

    • If yes: Right arrow into rectangle indicating "Attempt to develop test conditions and acceptance criteria which can distinguish batches with unacceptable bioavailability."
    • If no: Downward arrow into diamond indicating "Do changes in formulation or manufacturing variables affect dissolution? (Use appropriate ranges. Evaluate dissolution within pH 1.2-6.8)."
      • If yes: Rightward arrow into diamond indicating "Are these changes controlled by another procedure and acceptance criterion?"
        • If yes: Diagonal left downward arrow into rectangle indicating "Adopt appropriate test conditions and acceptance criteria without regard to discriminating power, to pass clinically acceptable batches."
        • If no: Downward arrow into rectangle indicating "Adopt test conditions and acceptance criteria which can distinguish these changes. Generally, single point acceptance criteria are acceptable."
      • If no: Downward arrow into rectangle indicating "Adopt appropriate test conditions and acceptance criteria without regard to discriminating power, to pass clinically acceptable batches."
  3. What are appropriate acceptance ranges? (extended release)

    Diamond indicating "Are bioavailability data available for batches with different drug release rates?"

    • If no: Right arrow into diamond indicating "Is drug release independent of in vitro conditions?"
      • If no: Downward arrow into rectangle indicating "Use all available stability, clinical, and bioavailability data to establish appropriate acceptable ranges."
      • If yes: Diagonal left downward arrow into diamond indicating "Can in vitro/in vivo relationship be established? (Modify in vitro conditions if appropriate.)"
    • If yes: Downward arrow into diamond indicating "Can in vitro/in vivo relationship be established? (Modify in vitro conditions if appropriate.)"
      • If yes: Downward arrow into rectangle indicating "Use the in vitro/in vivo correlation, along with appropriate batch data, to establish acceptance ranges."
      • If no: Right arrow into rectangle indicating "Use all available stability, clinical, and bioavailability data to establish appropriate acceptable ranges."
      • Diagonal left downward arrow into diamond indicating "Are acceptance ranges less than 20% of the labeled content?"
        • If yes: Right arrow into rectangle indicating "Provide appropriate bioavailability data to validate the acceptance ranges."
        • Downward arrow into Finalize acceptance ranges.
        • If no: Downward arrow into Finalize acceptance ranges.

Decision #8: Microbiological Attributes of Non-Sterile Drug Products

Diamond indicating "Does the product contain antimicrobial preservatives or possess inherent antimicrobial activity?"

  • If yes: Right downward arrow intro rectangle indicating "Establish preservative chemical acceptance criteria and perform preservative effectiveness evaluation of product containing less than or equal to the minimum specified preservative concentration, or demonstrate the inherent antimicrobial activity of the drug product."
    • Downward arrow into rectangle indicating "Establish microbial limit acceptance criteria as per the harmonized pharmacopeia monograph."
    • Downward arrow into rectangle indicating "Perform microbial limits testing on a lot-by-lot basis."
    • Downward arrow into diamond indicating "Do production lots consistently meet microbial limits acceptance criteria?"
      • If yes: Downward arrow into rectangle indicating "Perform skip-lot testing for microbial limits, or provide scientific justification for no routine microbial limits testing."
      • Left upward arrow looping back to diamond indicating "Do production lots consistently meet microbial limits acceptance criteria?"
      • If no: Right upward arrow looping back to rectangle indicating "Perform microbial limits testing on a lot-by-lot basis."
  • If no: Left downward arrow into diamond indicating "Is the drug product a dry dosage form (e.g. solid oral or dry powder)?"
    • If yes: Downward arrow into diamond indicating "Does scientific evidence demonstrate growth inhibitory properties of the drug product?"
      • If yes: Downward arrow into rectangle indicating "Microbial limits acceptance criteria and testing may not be necessary."
      • If no: Right arrow into rectangle indicating "Establish microbial limit acceptance criteria as per the harmonized pharmacopeia monograph."
    • If no: Right arrow into rectangle indicating "Establish microbial limit acceptance criteria as per the harmonized pharmacopeia monograph."

Page details

Date modified: