3. Scope
3.1. Subject to section 3.2 and 3.3, these Guidelines set NOx emission limits for new combustion turbines with a power rating equal to or greater than 1 MW.
3.2. These Guidelines do not apply to the following :
- emergency combustion turbines;
- combustion turbines used solely for purposes of research, development and field demonstration; and
- combustion turbines under repair or those being tested during commissioning or during verification of repairs.
3.3. Section 4 of these Guidelines does not apply to peaking combustion turbines with a power rating of less than 4 MW. However, the other sections of these Guidelines should still be met.