Enhanced Fujita scale damage indicators and degrees of damage, chapter 10


Strip Malls (SM)

Typical Construction:

Table 10. Degree of Damage (DOD) for Expected (EXP), Lower Bound (LB) and Upper Bound (UB)
DOD Damage Description EXP* LB* UB*
1 Threshold of visible damage 105 85 130
2 Uplift of roof covering at eaves and roof corners 130 105 160
3 Broken windows or glass doors 140 115 170
4 Uplift of roof decking 165 135 195
5 Collapsed façade or parapet walls 165 135 200
6 Covered walkways uplifted or collapsed 165 140 200
7 Uplift or collapse of entire roof structure 195 165 230
8 Collapse of exterior walls; closely spaced interior walls remain standing 225 190 265
9 Complete destruction of all or a large section of building 275 235 320

*All wind speeds in km/h

Page details