Wood preservation facilities, ammoniacal copper zinc arsenate: chapter C, table 20


Table 20. Additional Recommended Operating Practices for Process Systems

(Use in conjunction with Part I, Chapter A - General Recommendations for all Wood Preservatives, Table 20.)

Operation Recommendations
Treatment process
  • After pressure treating, apply a final vacuum of maximum 25 kPa for at least 2 hours. The retort should be heated to between 80 and 100ÂșC during the vacuum process.
  • After removal from the retort, keep the materials on the drip pad/holding area until all dripping has ceased.