Wood preservation facilities, general recommendations: chapter A, table 15


Table 15. Recommended Design Features for Kilns and Accelerated Fixation Areas (All Preservatives)

Objectives:

Design feature Recommendations
General design
  • Consider integrated design provisions for
    • area that is sheltered from precipitation, dust, debris;
    • adequate air flow;
    • sufficient heat and humidity to achieve fixation or promote stabilization.
Drip and containment
  • Should have an impermeable floor and be designed so that any residues may easily be cleaned up.
  • Should be fully contained with sufficient grade and an efficient drainage system to direct any free liquid to a collection and recycling system.
  • Fluids should be returned to the treatment process with minimum dispersal from tracking by personnel and vehicles.