Guidance on efficacy requirements for biocides: Preparing your benefits package
On this page
Summary of benefits information
Certain applications must contain a summary of the information included in your application about the benefits and any related uncertainties of your biocide. Find information on when an efficacy summary is required and what should be included in the efficacy summary.
Do not include detailed information on efficacy data reporting in your summary.
The efficacy summary should include a summary of the efficacy reports submitted in support of the benefits of your biocide.
Organisms used
You should include the following information for the test organisms you used in each efficacy study:
- name
- source (stock supplier)
- for example, the American Type Culture Collection (ATCC) identifier and the American Society of Testing and Materials (ASTM) identifier
- identity of the specific strain, if applicable
You should also specify the purpose of the study, such as:
- adding a claim or
- confirmatory data and the changed condition that prompted confirmatory testing (refer to summary table below for an example)
Test product
For each efficacy study, describe the test product formulation used in each batch test, including :
- name of the test product
- application method used in testing
- for example, immersion, spray, towelettes
- ready-to-use (RTU) product or dilution used (for biocides that are diluted from a concentrated formulation) and its definition in testing
- for example, 1:256 (1 part product in 256 parts water)
- tested contact time
If you are referencing efficacy data from another biocide to support a claim, refer to the example summary template for how to indicate this.
Batches and carriers
For each efficacy study, indicate:
- the number of batches used
- the number of carriers used per batch
- the type of carrier used
- for example, steel disk, cotton and polyester swatches
Organic burden level (soil load)
For each efficacy study, indicate:
- the specific burden load
- for example, 5% fetal bovine serum (FBS) or no soil load
Test method
For each efficacy study, indicate the:
- name of the current test method (with additional information about modifications, if any)
- for example, ASTM 961.02 (modified for mycobacteria)
Performance criteria (results)
For each efficacy study, as per prescribed test method used, indicate the:
- quantitative or qualitative results for each batch
- for example, greater than or equal to 3 log10 reduction in viral titer beyond the cytotoxic level for all the test carriers or 59/60 carriers negative for growth, as appropriate
Laboratory report identifier
For each efficacy study, indicate the:
- unique identification number of your efficacy report
- for example:
- 506-259 (Laboratory Project Identification Number) or
- 506-259 (Project Number) or
- 2304884-404 (Laboratory Study Number)
- for example:
Other information
If it applies, you should also provide:
- post-meeting notes of pre-submission meetings or discussions
- any correspondence related to your submission (for example, emails)
- reason(s) for submitting new efficacy data
- for previously approved claims against specific micro-organisms
- your biocide's regulatory status in foreign jurisdictions and any differences in its efficacy profile
Example of a summary template for efficacy data
To summarize your efficacy data for a biocide, use:
- the following template or
- a different format that contains the same information
The summary should outline the:
- new or revised (in the case of a post-authorization change) claims for your biocide for each microbial category and
- data to support the claims
Purpose of the study and organism | Test product name, application method, RTU or dilution, and contact time
Or Cross-referenced identification number of biocide |
Number of batches and carriers, carrier type | Soil load | Test method | Reported performance criteria | Report identifier |
---|---|---|---|---|---|---|
Hard surface disinfection claims | ||||||
Bacteria | ||||||
Addition of general (broad-spectrum) and specific claims against Staphylococcus aureus (ATCC 6538) | "Test product name", Immersion, 1:256 (1 part product in 256 parts water), 5 minutes | 3 batches 60 carriers/batch, steel disk |
5% FBS | AOAC 955.15 | Batch #1: 59/60 negative for growth Batch #2: 60/60 negative for growth Batch #3: 58/60 negative for growth |
A38573 |
Addition of general (broad-spectrum) and specific claims against Pseudomonas aeruginosa (ATCC 15442) | "Test product name", Immersion, 1:256 (1 part product in 256 parts water), 5 minutes | 3 batches 60 carriers/batch, steel disk |
5% FBS | AOAC 964.02 | Batch #1: 54/60 negative for growth Batch #2: 56/60 negative for growth Batch #3: 55/60 negative for growth |
A38574 |
Confirmatory data to reduce contact time to 4 minutes for hard-surface disinfection claims against all bacteria Staphylococcus aureus (ATCC 6538) |
"Test product name", Immersion, 1:256 (1 part product in 256 parts water), 3 minutes and 54 seconds | 2 batches 10 carriers/batch, steel disk |
5% FBS | AOAC 955.15 | 10/10 carrier negative for growth per batch | A32450 |
Confirmatory data to reduce contact time to 4 minutes for hard-surface disinfection claims against all bacteria Pseudomonas aeruginosa (ATCC 15442) |
"Test product name", Immersion, 1:256 (1 part product in 256 parts water), 3 minutes and 54 seconds | 2 batches 10 carriers/batch, steel disk |
5% FBS | AOAC 964.02 | 10/10 carrier negative for growth per batch | A32451 |
Addition of claim against Campylobacter jejuni (ATCC 29428) | "Test product name", Immersion, 1:256 (1 part product in 256 parts water), 3 minutes and 54 seconds | 2 batches 10 carriers/batch, steel disk |
5% FBS | AOAC Use-Dilution Method | 10/10 carrier negative for growth per batch | A38547 |
Addition of a claim against Klebsiella pneumoniae (ATCC 4352) | Reference biocide identification number | |||||
Viruses | ||||||
Addition of a claim against Rhinovirus type 37 (ATCC VR-1607), Strain 151-1 | "Test product name", RTU spray | 2 batches carrier/batch |
No soil load | ASTM E1053 | 3.25 log10 reduction in viral titer per carrier beyond the cytotoxic level for all the test carriers | A38647 |
Abbreviation: AOAC: Association of Official Analytical Collaboration ASTM: American Society of Testing and Materials FBS: Fetal Bovine Serum Data may be referenced from an existing authorized biocide if:
|
Page details