2010 Dose Data from the Fixed Point Surveillance Network

The Fixed Point Surveillance (FPS) network monitors public radiation dose due to radioactive materials in the atmosphere. The FPS network is used primarily to measure the external dose from three noble gases in particular; Argon-41, Xenon-133 and Xenon-135, as well as the total combined external dose from all sources, measured as Total Air KERMA.

Gentilly System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Leprad Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 16124 14992 18797                  
Boulevard Alphonse-Deshaies Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 12403 11172 15960                  
Port Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 6996 6128 8125                  
Victoriaville Argon-41 - - x                  
Xenon-133 - - x                  
Xenon-135 - - x                  
Total Air KERMA 14813 13875 x                  
Trois Rivières Argon-41 x x x                  
Xenon-133 x x x                  
Xenon-135 x x x                  
Total Air KERMA x x x                  
Québec City Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 6697 6346 7761                  
Batiscan Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15524 12253 17893                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Bruce System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Site Boundary Argon-41 - 8 28                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 12038 9743 13371                  
Scott Point Argon-41 x x x                  
Xenon-133 x x x                  
Xenon-135 x x x                  
Total Air KERMA x x x                  
Kincardine Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 10363 8662 10829                  
Inverhuron Argon-41 - - 34                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 9740 7636 10460                  
Port Elgin Argon-41 - - 7                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 8441 6060 9320                  
Infocentre Argon-41 x x x                  
Xenon-133 x x x                  
Xenon-135 x x x                  
Total Air KERMA x x x                  
Tiverton Argon-41 - x x                  
Xenon-133 - x x                  
Xenon-135 - x x                  
Total Air KERMA 11209 x x                  
Shore Road Argon-41 - 54 -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 9356 7260 9939                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Greater Toronto Area System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Scarborough Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 10552 8897 10279                  
Bowmanville Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 17270 15101 17395                  
Resources Road Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 8346 6947 8055                  
St. Clair Avenue East Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 12514 10758 12245                  
Pickering Argon-41 - - 7                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15786 13726 15829                  
Oshawa Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 14864 13034 14955                  
Markham Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15924 14035 16319                  
Ajax Argon-41 x x x                  
Xenon-133 x x x                  
Xenon-135 x x x                  
Total Air KERMA x x x                  
Port Hope Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 17551 15244 17423                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Darlington System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Blue Circle Cement Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 13897 11731 13798                  
Bowmanville Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 17025 14981 17409                  
Site #3 Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 18460 16549 19124                  
Site #4 Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15430 13581 15868                  
Site #5 Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 14485 12878 15057                  
Site #6 Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 19424 17132 19567                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Pickering System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Montgomery Road Argon-41 121 54 287                  
Xenon-133 - - 6                  
Xenon-135 - - -                  
Total Air KERMA 14896 12798 15163                  
Kinsmen Park Argon-41 9 10 62                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15141 13313 15330                  
Liverpool Road Argon-4 - 11 24                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15258 13302 15562                  
East Boundary Argon-41 131 145 168                  
Xenon-133 - - 3                  
Xenon-135 - - -                  
Total Air KERMA 20439 18109 20902                  
Central Maintenance Argon-41 11 13 265                  
Xenon-133 - - 4                  
Xenon-135 - - -                  
Total Air KERMA 11412 9845 11744                  
Beachpoint Promenade Argon-41 11 - 25                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 10800 9044 10766                  
Petticoat Creek Argon-41 17 - 46                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15862 13313 15855                  
CMS Storage Yard Argon-41 26 21 331                  
Xenon-133 - - 6                  
Xenon-135 - - -                  
Total Air KERMA 9573 8131 9735                  
Alex Robertson Road Argon-41 - 8 39                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 18947 16125 19280                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Ottawa Valley System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Chapeau Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 15019 13093 18213                  
Chalk River Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 24247 20223 29083                  
Deep River Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 21906 18391 25541                  
Ottawa Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 9607 9212 12009                  
Petawawa Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 13798 12086 17490                  
Sheenboro Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 13860 12192 17730                  
Westmeath Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 13146 10915 15348                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Regional System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Amherstburg Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 16116 13615 15924                  
Vancouver Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 14565 13044 13808                  
Yellowknife Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 17049 14232 15119                  
Regina Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 20659 15838 16425                  
Calgary Argon-41 x x x                  
Xenon-133 x x x                  
Xenon-135 x x x                  
Total Air KERMA x x x                  
Winnipeg Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 12079 9923 11836                  
Thunder Bay Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 13868 11855 14023                  
Montréal Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 13352 12029 13619                  
Charlottetown Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 16193 14100 16456                  
St. John's Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 21392 17748 21213                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Point Lepreau System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Lighthouse Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 21661 21469 24942                  
Digby Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 32572 29359 33631                  
Dipper Harbour Argon-41 x x x                  
Xenon-133 x x x                  
Xenon-135 - - -                  
Total Air KERMA x x 27498                  
Emergency Centre Argon-41 x x x                  
Xenon-133 x x x                  
Xenon-135 - - -                  
Total Air KERMA x x 37122                  
Saint John Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 19845 19156 21357                  
Welch Cove Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 11873 11675 15960                  
Kingston Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 16675 15443 18732                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Vancouver Island System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Saanich Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 11349 9909 10580                  
Metchosin Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 8816 7763 8265                  
Victoria Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 7669 6630 7003                  
Nanaimo Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 11667 10428 10717                  
Sidney Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 12366 10915 11554                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Halifax System - 2010

Dose Data (nGy/month)
Station Nuclide JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
West Street Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 23017 21858 24799                  
Dartmouth Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 21734 19998 23482                  
Cole Harbour Road Argon-41 - - -                  
Xenon-133 - - -                  
Xenon-135 - - -                  
Total Air KERMA 21967 20007 23672                  
nGy (nanoGray)

A Gray (Gy) is a standard unit of measurement for radiation dose, defined as 1 Joule of energy deposited per kilogram of matter. A nanoGray (nGy) is 1×10-9 Grays and it is a much more common unit of measure for these types of very low doses.

KERMA (Kinetic Energy Released in Matter)

In this case the 'Total Air KERMA' refers to the radiation dose from all external gamma sources, not just from the three noble gases Argon-41, Xenon-133 and Xenon-135. This includes natural background radiation as well, such as from mineral deposits in the ground, radon gas in the air or cosmic radiation from space.

- (hyphen)

The system has a limit on the amount of low-level radiation it can reliably detect and use to calculate a monthly dose and the hyphens represent any data which falls below this detection limit. The minimum detectable dose for the three noble gases being monitored are...

  • 6 nGy/month for Argon-41
  • 3 nGy/month for Xenon-133
  • 3 nGy/month for Xenon-135

These detection limits are well below the acceptable public dose limit of 1,000,000 nGy/year as published by the  Canadian Nuclear Safety Commission in their  Radiation Protection Regulations.

x

The dose data for this month was not collected due to a problem with the equipment or data transfer.

Page details

2021-01-08